当前位置:首页 > 产品选型 > 气体配比设备 > 产品详情
气体混气仪,气体混合仪,气体配比器,气体

2000 Flux Controller Display-LFIX 气体混气仪 特点:气路质量流量控制,响应时间1~4SEC,******耐高3MPa气体混合,高精度控制多种气体混合比例,实现不同气体比要求,气路通道:1~8路(根据客户需求设计)。

详细介绍

Preface

Please read these operating instructions before commissioning the instrument.

1.1 The instrument pass strict test .All necessary settings are described in this manual. If any difficulties should

 arise during commissioning ,you are asked not to carry out any manipulations that could endanger your rights

 under the instrument warranty!

1.2 The installation site should be free from vibration. Electromagnetic fields, caused by motors, transformers etc

. should be avoided.

1.3 Installation, operation, and maintenance of the recorder should only be performed by properly trained personnel.

1.4 The screen can not be hit.

2. purpose and characteristic

The paperless recorder offer power to MFC and MFM, flux reckoning, display real time value of flux and cumulate 

value of flux. And can be used with any brand of MFC and MFM.

   This instrument’s DOS is made by plastic and it is small, easy install. Input and output single include DC(0-5V),

 analog(4-20 ma), have alarm function.

Technical Data

1. Output Power  +15V±5% 500mA    -15V±5% 500mA

2. Benchmark Fountain  +5.00V±0.1% 5mA

3.Power Supply   85VAC-265VAC,50Hz±5%

4.Input And Output Single  voltage 0-50V, current 4-20mA

5.Display 128*64 pixel, LED

6: Most Cost  8W

7: Control Channel  one channel display

8: Error  ±0.2%FS

9:Environment Temperature  0-50℃

10:Environment Humidity  0-85%RH

11:Safety Grade  IP40

12:Communication Port  RS232

Work Elements

1、 use on-off power(±15V), have large voltage range and strong anti-jamming,

2、 benchmark fountain and flux set

output 0-5V single or 4-20mA single to control MFC’s flux. It is a soft start-up power, need 18s to start-up machine, so the voltage or analog can go to 5v or 20 mA slowness

3、 valve location set

set valve location on panel, “valve location” means common work., “wash” means wash pipeline.

4、 zero

adjust instrument’s zero through configuration.

5、 alarm

set flux high level and low level in configuration, when instantaneous flux out of the level ,display alarm signal 

6、 flux unit 

there are three kind of  unit(“SCCM”,“SLM”,“%”) to choose.

Installation And Connection

The installation site should be free from vibration. Electromagnetic fields, caused by motors, transformers etc.

 should be avoided.

The ambient temperature at the site should be 0 to +45°C, with a relative humidity of 75%, no condensation.

Interface And Operation Explain

1、Main Page

1: flux alarm: AH means high leave alarm, AL means low leave alarm. 

2: unit

3: engineering value of flux

4: cumulate time, unit is hr.

5: total accumulation, from 0 to 99999999.

6: state of valve location 

set valve location on panel, “VC” means common work., “WH” means wash pipeline, “CL” means close.

2. Value Page

Press  move cursor

Press ,change number

Press  display next page

Press , choose state of valve location, then move cursor to “OK” , press . 


3、Output Page

Press  move cursor

Press ,change number

Press  display next page

Zero set, when valve location is close or flux value is zero but display value is not zero, user can use this

 function. Attention : you must use this function when short circuit the input.

4: Password Page

Press  move cursor

Press ,change number

Press  and display next page for 2s, display password page

press  input password , and press , get into configuration page.

5.Configuration Page

 Press  move cursor

1:input: sub menu of input configuration

2:system: sub menu of system configuration

3: alarm: sub menu of alarm configuration

4: timer: sub menu of timer configuration

5:cumulate: sub menu of cumulate configuration

6: out: sub menu of out configuration

6.Input Page 

Press  move cursor

Press ,change number

1:signal type: “5V” means input single is 0-5V, “20mA” means input single is 0-20mA.

Please set zero before change signal type.( set zero when voltage is 0V or current is 4mA.

2:unit

3:filt,filter the waves, from 0.0s to 9.9s.

4:range, from –9999 to 30000, press  change station of radix point.

5:y=Kx+B

7System

1:set password

2: baud: 1200、2400、9600

3:address range (0-255)

8: Alarm

l Press  move cursor;

l Press ,change number;

1:AL:low alarm 

2:AH: high alarm

9、Timer

l Press  move cursor;

l Press ,change number;

10、Cumulate

1: cumulate ratio, use cumulate ratio adjust resolution of cumulate when its value is too small.

2:cumulate time

3:clear: “Y ” reset cumulate.

11、Output

l press  move cursor;

l press , change number;

l press  display next page;

1: output time

2: output percent

3: reset, “Y” reset output value to zero.

Software

Communication set

1: Open DSN2000 Software. 

2: Choose Setting →com set, display com. Setting page.

l in this page user can set address and baud rate, and the parameter must the same as instrument.

l choose communication port (from COM1 to COM4 )bases on user’s computer port.

l Parity must be None.

l Interval is software receive data’s interval time.

3:Real Time Curve

user can use this software look-in real time curve. Press file →(Acquire Real-Time Data)or  to display real data fetch.And then press  to start fetch data.You can see the real curve in this page.

4.Other Information

Press View → Real-Time Curve → other information . You can get MulCumulation , TimeCumulation ,

 ValueSet and Output.

5.Mass Flow Conversion Factors

GAS

GASCODE

(SEMIE52-0302)

HEAT

(Cal/g)

Þ

(g/l 0℃)

Factors

Air 

008

0.2400

1.2930

1.006

Ar 

004

0.1250

1.7837

1.415

AsH3 

035

0.1168

3.4780

0.673

BBr3

079

0.0647

11.1800

0.378

BCl3

070

0.1217

5.2270

0.430

BF3

048

0.1779

3.0250

0.508

B2H6 

058

0.5020

1.2350

0.441

CCl4

101

0.1297

6.8600

0.307

CF4

063

0.1659

3.9636

0.428

CH4

028

0.5318

0.7150

0.719

C2H2

042

0.4049

1.1620

0.581

C2H4 

038

0.3658

1.2510

0.598

C2H6

054

0.4241

1.3420

0.481

C3H4

068

0.3633

1.7870

0.421

C3H6 

069

0.3659

1.8770

0.398

C3H8 

089

0.3990

1.9670

0.348

C4H6

093

0.3515

2.4130

0.322

C4H8 

104

0.3723

2.5030

0.294

C4H10 

111

0.4130

2.5930

0.255

C5H12 

240

0.3916

3.2190

0.217

CH3OH 

176

0.3277

1.4300

0.584

C2H6O 

073

0.3398

2.0550

0.392

C2H3Cl3 

112

0.1654

5.9500

0.278

CO 

009

0.2488

1.2500

1.000

CO2 

025

0.2017

1.9640

0.737

C2N2 

059

0.2608

2.3220

0.452

Cl2 

019

0.1145

3.1630

0.858

D2 

014

1.7325

0.1798

0.998

F2 

018

0.1970

1.6950

0.931

GeCl

113

0.1072

9.5650

0.267

GeH4 

043

0.1405

3.4180

0.569

H2 

007

3.4224

0.0899

1.010

HBr

010

0.0861

3.6100

1.000

HCl

011

0.1911

1.6270

1.000

HF 

012

0.3482

0.8930

1.000

HI 

017

0.0545

5.7070

0.999

H2S 

022

0.2278

1.5200

0.844

He

001

1.2418

0.1786

1.415

Kr 

005

0.0593

3.7390

1.415

N2 

013

0.2486

1.2500

1.000

Ne 

002

0.2464

0.9000

1.415

NH3 

029

0.5005

0.7600

0.719

NO 

016

0.2378

1.3390

0.976

NO2

026

0.1923

2.0520

0.741

N2O

        027

0.2098

1.9640

0.709

O2

015

0.2196

1.4270

0.992

PCl3

193

0.1247

6.1270

0.358

PH3 

031

0.2610

1.5170

0.691

PF5

143

0.1611

5.6200

0.302

POCl3

102

0.1324

6.8450

0.302

SiCl4

108

0.1270

7.5847

0.284

SiF4

088

0.1692

4.6430

0.348

SiH4

039

0.3189

1.4330

0.599

SiH2Cl2

067

0.1472

4.5060

0.412

SiHCl3

147

0.1332

6.0430

0.340

SF6

110

0.1588

6.5160

0.264

SO2

032

0.1489

2.8580

0.687

TiCl4

114

0.1572

8.4650

0.206

WF6

121

0.0956

13.2900

0.215

Xe 

006

0.0379

5.8580

1.415